The error "the hardware information does not match with your dongle" in Autodata 3.45 typically occurs because the software's license file is tied to a specific hardware ID (UID) that no longer matches your current system. This common issue happens after hardware upgrades, reinstallations, or if the initial license generation was incorrect. How to Fix the Hardware Mismatch Error
To resolve this, you must re-generate a valid license file using your current PC's hardware ID. 1. Retrieve Your Current Hardware ID (UID) Navigate to your Autodata installation or "Keygen" folder.
Open the folder matching your system type: GetUid-x86 (for 32-bit) or GetUid-x64 (for 64-bit).
Right-click the GetUid executable and select Run as Administrator.
Note your code: A window will appear showing an 8-digit (32-bit) or 10-digit (64-bit) code. This is your unique UID.
Tip: If the code is 6400000000, restart your PC and try again, as this is an invalid ID. 2. Generate a New License File
Find the tool named License_builder.exe or a similar .bat file (often called License example.bat) in your "Keygen" folder.
If using a .bat file, right-click it and select Edit. Replace the existing ID with your new UID and save.
Run the file to generate a new registry file (e.g., license_Autodata.reg). 3. Register and Restart the Emulator The error "the hardware information does not match
Double-click the newly generated .reg file and click Yes to import the settings into your Windows registry. Restart your computer.
Open the Emulator (often found in C:\ADCDA2\ or through the start menu under "nodongle.biz") and ensure it is running with a "green light" or active status. Troubleshooting Tips Creating Autodata License Guide | PDF | Computers - Scribd
The error "the hardware information does not match with your dongle" typically occurs when the unique hardware ID (UID) of your computer does not align with the license registry file used by the Autodata 3.45 emulator. This usually stems from hardware changes, incorrect installation steps, or a failure to properly "sign" the emulator files on modern versions of Windows. Common Causes
Hardware Mismatch: The license file was generated for a different computer or a different hardware configuration (e.g., a new motherboard or network card).
Missing Test Mode: On Windows 7, 8, or 10, the system must be in Test Mode to allow unsigned emulator drivers to run.
Incorrect UID: The 8 or 10-digit UID used to generate the .reg license file was captured incorrectly.
Regional Settings: In some cases, regional settings not set to English (United States) can cause startup errors. Troubleshooting and Resolution Steps
Enable Test Mode and Sign DriversModern Windows versions block the virtual dongle drivers by default. You must use a tool like DSEO (Driver Signature Enforcement Overrider) to enable "Test Mode". After enabling it, you must reboot; a "Test Mode" watermark should appear on your desktop. Motherboard replacement (most common cause – e
Verify the Hardware ID (UID)Run the GetUid-x86 or GetUid-x64 utility (depending on your OS) as an Administrator.
Note: If your UID appears as "6400000000", it is invalid; you must reboot and try again.
Registry Generation: Ensure the license registry file you are using was created using this specific UID.
Clean and Reinstall Sentinel DriversCorruption in the Sentinel key settings can cause matching errors. Uninstall the existing Sentinel software.
Run a cleanup utility like SSD Cleanup to remove residual driver data.
Reinstall the Sentinel protection installer and then the hardware key emulator files. Check Registry and Regional Settings
Ensure you have imported the correct registry settings for your architecture (32-bit vs. 64-bit).
If the software still fails to launch, try changing your computer's Regional Settings to "English (United States)" through the Control Panel. Solution 2: Full Deactivation and Reactivation (For Dongles
Restart the EmulatorAlways run the emulator (often a green traffic light icon or AuDaS0) as an Administrator. It may take 2–4 minutes for the drivers to fully initialize. Autodata 3.45 Installation Guide | PDF - Scribd
Problem: "Autodata 345 — hardware information does not match with your dongle top"
Understanding the Error
To understand the fix, you must first understand how Autodata 3.45 was protected. The software utilizes a hardware dongle protection system (specifically a SafeNet Sentinel or Rainbow Technologies dongle). The software checks for the presence of this physical USB key upon startup.
In the context of widespread installations today, most users are running "cracked" or "fixed" versions of the software that emulate the dongle. The error usually appears because the software’s Driver is not correctly communicating with the Dongle Emulator, or the USB Drivers installed by default by Windows are blocking the communication.
✅ Use a dedicated PC for Autodata 345
Keep an old laptop or desktop running Windows 7 or Windows 10 LTSC strictly for Autodata. Disable Windows updates and disconnect it from the internet.
Summary
Autodata 345 reports a mismatch between the vehicle/hardware information and the dongle top (dongle identity). This prevents successful connection, unlocking, or data transfer between the diagnostic software and the vehicle. Root causes are typically dongle registration/incompatibility, corrupted dongle data, software version mismatch, or altered/incorrect vehicle interface settings.
What Causes Error 345?
The AutoData dongle (typically a Sentinel or HASP key) stores a unique "hardware fingerprint" of the original computer where the software was first installed. The error occurs when one or more of the following system components no longer match the fingerprint:
- Motherboard replacement (most common cause – e.g., after a repair or upgrade).
- Network adapter (MAC address) change – including switching from Ethernet to Wi-Fi or adding a new adapter.
- Processor (CPU) or hard disk serial number change – due to hardware failure or upgrade.
- Operating system reinstallation – if the dongle driver’s original system ID was overwritten.
- Using the dongle on a different computer – AutoData licenses are often locked to a single machine.
Solution 2: Full Deactivation and Reactivation (For Dongles from Another PC)
If you moved from PC-A to PC-B and kept the same dongle, the hardware mismatch is permanent. You must deactivate the old fingerprint.
For legitimate license holders:
- Recover the original PC (PC-A) where the dongle was last working.
- Open AutoData on PC-A.
- Go to Help → License → Deactivate / Unregister.
- Unplug the dongle from PC-A.
- Plug the dongle into PC-B (the new PC).
- Launch AutoData. It will now treat the dongle as new and allow you to register using your original serial number and activation code.
- If PC-A is dead or formatted, you must contact AutoData support with proof of purchase (invoice, dongle serial number). They can remotely reset the dongle's binding.
Understanding the Error
- Autodata 3.45: This is a version of software used for automotive diagnostics and data. It's designed to provide detailed information and diagnostic capabilities for vehicles.
- Dongle: A dongle is a small hardware device that is plugged into a computer to provide a form of software protection. It's often used by software developers to prevent unauthorized use of their products.
Method 3: Disable Antivirus / Add Exclusions
Modern antivirus software (Windows Defender, Norton, Avast) often identifies the dongle emulation software used by Autodata 3.45 as a "HackTool" or "Trojan" and deletes it or blocks its execution. This results in the "Hardware does not match" error.
- Open your Antivirus software (e.g., Windows Security).
- Go to Virus & threat protection > Manage settings.
- Scroll down to Exclusions and click Add or remove exclusions.
- Add the entire Autodata installation folder (e.g.,
C:\ADCDA2) as an exclusion. - Important: If you suspect the antivirus already deleted a crucial file, you may need to uninstall Autodata, disable the antivirus, and reinstall Autodata fresh.
- Note: Once installed, re-enable your antivirus.