The Daikin BRC4C160 is a specialized wireless infrared remote control used primarily with Daikin VRV, SkyAir, and other commercial and residential air conditioning units. This guide provides a comprehensive overview based on the official Daikin BRC4C Series Operation Manual to help you master its features, settings, and troubleshooting. Core Buttons and Controls
The BRC4C160 features a clean interface with several buttons hidden under a sliding front cover for advanced programming.
ON/OFF Button: Starts or stops the system with a single press. The operation lamp on the indoor receiver will light up in red when active.
Mode Selector: Cycles through the available operation modes: Cool, Heat, Dry, Fan, and Auto. Daikin Brc4c160 Manual
Temperature Adjustment: Use the UP and DOWN buttons to set your desired room temperature. Most Daikin units allow a range between
Fan Speed Control: Switches between High and Low airflow settings.
Swing Button: Adjusts the vertical airflow direction (flaps) to prevent direct cold drafts or to circulate air more effectively. The Daikin BRC4C160 is a specialized wireless infrared
Filter Sign Reset: Used to clear the "Time to Clean Filter" indicator on the display after you have performed maintenance on the indoor unit's air filter. Operating Modes Explained
Understanding how each mode functions ensures maximum comfort and energy efficiency: Wireless Remote Controller Kit - Daikin Europe
Inside the back cover of the BRC4C160, there is a small bank of DIP switches. The installation manual explains each one: Critical: If the system reads room temperature incorrectly
| Switch | Setting | Function | |--------|---------|----------| | DS1-1 | OFF (default) | Temperature sensor: Uses indoor unit sensor | | DS1-1 | ON | Temperature sensor: Uses remote controller’s built-in sensor | | DS1-2 | OFF | Standard operation | | DS1-2 | ON | Celsius / Fahrenheit selection (ON = Fahrenheit) | | DS1-3 | OFF | No function (reserved) | | DS1-4 | OFF | Normal mode |
Critical: If the system reads room temperature incorrectly (e.g., cold location near a door), set DS1-1 to ON to use the remote’s local sensor.
A: The manual does not have a one-button reset. You must cut power at the breaker for 10 minutes. To reset just the timer settings, press "Timer" and "Cancel" simultaneously for 10 seconds.
When the "Filter" icon appears, it means the unit has accumulated 2,500 operating hours. After cleaning the air filter, press the "Filter" button for 2 seconds (or use the combination in the manual) to reset the timer.