Mitsubishi Easysocket Usb Driver Windows 7 Zip Link ⇒ < ULTIMATE >
The Mitsubishi Easysocket USB driver is typically included within the installation folders of MELSOFT engineering software like GX Works2 or GX Developer. If you are looking for a standalone ZIP file or a link to the driver, you can find it through the following methods: Direct Download Links
You can find compatible drivers for Windows 7 (32-bit and 64-bit) on these third-party driver repository sites:
DriverScape: Offers Easysocket Driver Version 4.0.0.0 (approx. 19.37 KB).
Treexy: Lists Easysocket Version 4.0.0.1 released in February 2017.
Mitsubishi Electric FA Support: Official software updates and manuals can be found on the Mitsubishi Electric Factory Automation Global Website. Local Installation Path
If you already have Mitsubishi software installed, the driver files are already on your computer. You can manually point Windows to these directories to install the driver:
GX Works2: C:\Program Files (x86)\MELSOFT\Easysocket\USBDrivers GX Developer: C:\MELSEC\Easysocket\USBdrivers Manual Installation Steps
Open Device Manager and locate the "Unknown Device" or "MELSEC" entry under USB controllers. Right-click and select Update Driver Software. Choose Browse my computer for driver software. mitsubishi easysocket usb driver windows 7 zip link
Navigate to one of the local paths listed above or the folder where you extracted your downloaded ZIP file. Click Install once "Easysocket USB Drivers" is identified. Download | MITSUBISHI ELECTRIC Factory Automation
The Mitsubishi EasySocket USB driver is typically not a standalone download but is included within Mitsubishi's programming software packages like GX Developer
. To install it on Windows 7, you generally need to point the Windows Device Manager to the driver folder within your software's installation directory. Download and Official Sources
Official drivers and software updates are available through the Mitsubishi Electric Factory Automation Download Center Software Bundles : The drivers are located in the installation files for GX Developer Registration
: Some official downloads require creating a "My Mitsubishi" account and registering your software ProductID on the Mitsubishi Software Portal Installation Steps for Windows 7
If your PC does not recognize the PLC (Programmable Logic Controller) when connected via USB, follow these manual installation steps: Connect the Device
: Plug the USB cable from the PLC or adapter (e.g., FX-USB-AW) into your computer. Open Device Manager : Right-click My Computer Device Manager Locate Unknown Device : Look for "Unknown Device" or "Mitsubishi PLC" under Other devices Ports (COM & LPT) Update Driver Right-click the device and select Update Driver Software "Browse my computer for driver software" Specify Folder Path The Mitsubishi Easysocket USB driver is typically included
: Browse to the EasySocket driver location. The default installation path for GX Works2 is: C:\Program Files (x86)\MELSOFT\EasySocket\USBDRIVERS (for 64-bit systems) C:\Program Files\MELSOFT\EasySocket\USBDRIVERS (for 32-bit systems) Note: For FX Series specifically, use: ...\EasySocket\FXOptionDrivers\FXUSBDrv Confirm Installation : Windows may show a security warning; select "Install this driver software anyway" to complete the process. Troubleshooting Manually Install Any Driver on Windows Computer
The Mitsubishi Easysocket USB driver for Windows 7 is primarily used for communication between a PC and Mitsubishi Programmable Logic Controllers (PLCs), such as the iQ-R, iQ-F, Q, and L series. While the driver is often bundled with MELSOFT programming software like GX Works2 or GX Developer, it can also be downloaded independently from specialized driver databases or extracted from existing software installations. Download Links & Sources
Official Mitsubishi Support: The most reliable way to obtain the correct driver for your specific hardware is through the Mitsubishi Electric Factory Automation Download Center.
Third-Party Repositories: Sites like DriverScape and DriverMax provide version 4.0.0.0 and 4.0.0.1 zip or archive files compatible with Windows 7 (32 and 64-bit). How to Install the Driver on Windows 7
If the driver does not install automatically when you connect your PLC, you can manually point Windows to the driver files.
Locate the Driver Folder: If you have MELSOFT software (GX Works2/3) installed, the driver is likely already on your computer at:
C:\Program Files (x86)\MELSOFT\EasySocket\USBDrivers (64-bit) C:\Program Files\MELSOFT\EasySocket\USBDrivers (32-bit) Step 3 – Manual Driver Installation
Open Device Manager: Connect your PLC via USB. Right-click "Computer" > "Manage" > "Device Manager." Look for an "Unknown Device" or "MELSEC" with a yellow warning icon.
Update Driver Software: Right-click the unknown device and select Update Driver Software.
Browse Manually: Select "Browse my computer for driver software" and navigate to the USBDrivers folder mentioned above.
Confirm Installation: Click "Next" and then "Install" when Windows identifies the driver as Easysocket USB Drivers from Mitsubishi Electric Corporation. Mitsubishi L Series USB Driver Location for GS-Works2
Step 3 – Manual Driver Installation
- Right-click the unknown device → Update Driver Software.
- Select Browse my computer for driver software.
- Click Browse and navigate to the extracted folder (look for
.inffiles). - Ensure Include subfolders is checked.
- Click Next.
- If a Windows security warning appears, choose Install this driver software anyway (only if the source is verified as Mitsubishi).
- After completion, the device should appear under Ports (COM & LPT) as “Mitsubishi EasySocket USB” or similar.
Option B: Direct ZIP (Legacy Archive – Use with Caution)
Some known, clean hashes for version 1.0.8.0 (WHQL certified for Win7) exist in archived Mitsubishi support forums. The filename typically is:
Easysocket_USB_Driver_Win7_x86_x64.zip
SHA-256 Checksum (verification): 1a2b3c4d5e6f... (contact Mitsubishi support for official hash).
🔒 Do not download from random file hosts. Check hash integrity. When in doubt, extract from original MELSOFT DVD or ISO.
Where to get the driver (how to find a ZIP)
- Official vendor/manufacturer sites are safest. Search for “Mitsubishi EasySocket USB driver Windows 7” or check Mitsubishi Electric’s support/download pages for the specific model.
- If the manufacturer provides a zip, it typically contains INF files, .sys driver files, and a README with installation steps.
- Verify filenames and digital signatures where possible. Avoid untrusted third‑party downloads.
Installation Procedure
Once you have the ZIP file or driver package:
- Extract the Files: If you downloaded a ZIP file, right-click and select "Extract All." Do not attempt to run the setup from inside the zipped folder.
- Run the Installer: Locate the
Setup.exefile within the extracted folder. Right-click and select "Run as Administrator." - Follow the Wizard: The Mitsubishi install wizard is straightforward. Accept the license agreement and click Next until the installation completes.
- Connect the Hardware: Do not plug in the PLC USB cable until the software installation is finished. After the install completes, plug in the cable.
- Verify the Connection:
- Open the Device Manager in Windows 7.
- Expand the Ports (COM & LPT) section.
- You should see a device listed as "Mitsubishi Electric Corp. FX USB-IF" or similar.
- Note the COM port number in parentheses (e.g., COM3). You will need this number to configure your GX Works/GX Developer connection settings.
4. Step-by-Step Installation on Windows 7 (ZIP Method)
Use MELSOFT Installer (EXE)
Download the MELSOFT Driver Pack (e.g., MELSOFT_DRIVER_PACK.exe). It unpacks and auto-installs EasySocket USB along with Ethernet and CC-Link drivers.
Verifying operation
- Open HyperTerminal or your Mitsubishi configuration software and select the COM port assigned to the device.
- Set baud rate and serial parameters per device documentation and test communication.