Siemens DIGSI 4 v4.95, released in late 2022, is a comprehensive software suite for configuring and operating SIPROTEC 4 protection relays. Available via the Siemens SiePortal, the package functions as a 30-day trial or full version, including tools like SIGRA for fault analysis and IEC 61850 configuration. For download and installation details, visit Siemens SiePortal

The DIGSI 4 V4.95 download is primarily valued for its comprehensive inclusion of all released device drivers, which can be installed individually and independently from the main software. This version serves as an intuitive engineering tool for configuring and evaluating SIPROTEC devices in industrial and energy distribution systems. Key Features of DIGSI 4 V4.95

All-in-One Installer: The installation file includes the professional software along with the IEC 61850 System Configurator, SIGRA (for disturbance record evaluation), and all released device drivers.

30-Day Trial Mode: If you do not have a license key, the full software is usable for 30 days without functional restrictions by entering "Trial" as the serial number during setup.

Clean Installation Support: This version is capable of performing a clean install even if no previous versions of DIGSI 4 are present on the machine.

Visual Logic Projection: Users can project logic visually using CFC (Continuous Function Chart) without requiring deep programming knowledge.

Assignment Matrix: Features a clear matrix for at-a-glance configuration of protection settings and commissioning. Download and Installation

Official Source: You can download the full version from the Siemens Industry Online Support (SiePortal).

Package Size: The complete DVD installation file is approximately 5.3 GB. Siemens Digsi 4.95 Download

Setup: Open Setup.exe after unpacking the downloaded file to select whether to install the core DIGSI 4 software or specific device drivers.

The official Siemens DIGSI 4 version 4.95 is the standard engineering software used to configure, parameterize, and operate SIPROTEC 4, SIPROTEC Compact, and legacy SIPROTEC 3 and 2 protection devices. Released to enhance commissioning and reduce downtime, this version includes all released device drivers in a single 5.3 GB package. Direct Download and Installation Guide

You can download the full version from the Siemens Industry Online Support portal.

Trial Access: If you do not have a license key, you can enter "Trial" as the serial number during setup to activate a 30-day trial with no functional restrictions. Installation Steps: Download and unpack the 5.3 GB ISO or installation file. Run Setup.exe with Administrator rights.

Select and install the DIGSI 4 software first, followed by the specific device drivers needed for your relays (e.g., 7SJ, 7SA, 7SD). Restart your computer to finalize the system activation. Key Features of DIGSI 4.95

Siemens DIGSI 4.95 is a specialized engineering software designed for the parameterization, commissioning, and operation of Siemens SIPROTEC protection devices. It serves as the primary interface for managing industrial and energy distribution systems. Overview and Capabilities

DIGSI 4.95 is the standard configuration tool for SIPROTEC 4, SIPROTEC Compact, and legacy SIPROTEC 2 and 3 devices. It allows users to:

Configure Protection Settings: Easily select and adjust specific protection functions through a visual interface. Siemens DIGSI 4 v4

Analyze Faults: Use the integrated SIGRA tool to visualize disturbance records and perform fast fault analysis.

Logic Programming: Create visual logic using the CFC Editor (Continuous Function Chart) without requiring advanced programming knowledge.

IEC 61850 Support: Features a System Configurator to import/export SCL files for vendor-neutral station design. Download and Installation Process

The official full version of DIGSI 4.95 is available through the Siemens Industry Online Support (SIOS) portal.

Registration: A free account on the Siemens Industry Online Support website is required to access the download files.

File Retrieval: Download the DIGSI 4 V4.95 DVD installation file, which is approximately 5.3 GB and includes all released device drivers.

Core Installation: Unpack the file and run Setup.exe. Users must have Administrator rights on their PC to install the software.

Device Drivers: After the main software is installed, you must install the specific device drivers (e.g., 7SJ, 7SA) needed for your site’s relays to enable communication. Step 4: License Dongle Driver

Prerequisites: For Windows 10 users, Microsoft .NET Framework V3.5 must be installed manually before beginning the DIGSI setup. Licensing and Trial

Trial Period: The software can be used as a 30-day trial version with no functional restrictions by entering the serial number "Trial" during setup.

Full Activation: For permanent use, a valid license key is required. Licenses can be managed and transferred using the Automation License Manager (ALM). System Requirements


Step 4: License Dongle Driver

  • After installation, connect your USB hardlock.
  • DIGSI 4.95 requires the Sentinel HASP driver. The installer usually installs it, but you can manually run \Tools\HASP\HASPUserSetup.exe.
  • Reboot.

3. Contact Your Local Siemens Distributor

If you cannot find it online, Siemens regional sales offices can provide a direct download link or a physical DVD along with a license key (typically delivered via email as a .lic file or a USB dongle).

Part 2: The Challenge of Downloading DIGSI 4.95

If you search for "Siemens Digsi 4.95 Download," you will encounter a minefield. Here is the truth:

Siemens does not offer DIGSI 4.95 as a public, free download.

Unlike open-source software, DIGSI is a proprietary commercial product. Siemens has retired DIGSI 4 from active sales and support. As of 2023-2025, Siemens’ primary download portal (the Industry Online Support or the Software Update Service) has removed DIGSI 4.95 from the “Public” section.

Option A: Existing Service Contract (Software Update Service – SUS)

If your company purchased a SUS agreement for DIGSI 4 before its discontinuation, you can still access the download via the Siemens Industry Online Support (SIOS).

  1. Go to support.industry.siemens.com.
  2. Log in with your company’s registered account.
  3. Navigate to “My Licenses” or “Software Downloads”.
  4. Filter by “DIGSI 4” – version 4.95 should appear if your contract is active.

"No valid license found"

  • Cause: The USB stick is not inserted, or the license is for an older version (e.g., V4.80).
  • Fix: Insert the stick. If the version is old, right-click the license in ALM and check if an upgrade is permissible (requires internet connection to Siemens server).