Siemens Pc Adapter Usb A2 Driver Windows Xp - Extra Quality . Satanath Records

Siemens Pc Adapter Usb A2 Driver Windows Xp - Extra Quality

Siemens SIMATIC PC Adapter USB A2 (Article Number: 6GK1571-0BA00-0AA0

) is an active communication gateway designed to connect a PG/PC or notebook to SIMATIC S7 systems via PROFIBUS or MPI. It serves as the successor to the original PC Adapter USB. System Compatibility Operating Systems : Supported on Windows XP (SP2 or higher) , Vista, and Windows 7 (32/64-bit). Hardware Interface : Compatible with USB V1.1, V2.0, and V3.0 ports. Software Integration

: The drivers are typically included when installing major Siemens engineering software such as STEP 7 (Classic or TIA Portal) , SIMATIC PDM, or Drive ES. Electric Automation Network Installation Guide for Windows XP For a manual installation using the PC Adapter USB A2 Driver Disk , follow these steps: Siemens SiePortal Preparation : Close all running programs and ensure you have Administrator rights

; the installation will fail at the Microsoft Visual C++ 2005 Redistributable step without them. Driver Execution from the driver CD or downloaded folder. Completion

: Once the "Simatic Device Drivers" installation finishes, restart the computer. Hardware Connection

: Plug the USB A2 adapter into a USB port. Windows XP should launch the "Found New Hardware Wizard."

: Select "Install the software automatically." After completion, the device will appear in the Device Manager Simatic Net as "Simatic PC Adapter USB A2". Siemens SiePortal Common Technical Issues Virtual Machine Errors siemens pc adapter usb a2 driver windows xp

: Users running XP on VMWare or VirtualBox may encounter internal errors (e.g., n_pnp.c(901)

). Resolving this often requires setting the VM's USB compatibility to

and ensuring the driver is accessed from a virtual disk rather than a shared folder. Interface Configuration

: In the "Set PG/PC Interface" utility, it is recommended to manually select

rather than "Auto," as automatic bus profile detection can sometimes fail. Power Requirements

: Unlike third-party adapters, the Siemens USB A2 is powered directly via the USB cable and provides electrical isolation between its interfaces. Siemens SiePortal for a specific error code or help configuring the PG/PC interface for a particular PLC? PC Adapter USB A2 6GK 1571-0BA00-0AA0 Drivers problem Siemens SIMATIC PC Adapter USB A2 (Article Number:

The Siemens SIMATIC PC Adapter USB A2 (6GK1571-0BA00-0AA0) is compatible with Windows XP Professional SP2 or higher . Drivers for this hardware are typically bundled with Siemens engineering software like STEP 7 or TIA Portal, but they can also be installed manually via a dedicated driver disk . Driver Installation Methods

Automatic (Software Bundle):Installing major Siemens software packages automatically includes the necessary "Simatic Device Drivers" . Simatic Manager (STEP 7) TIA Portal Simatic Net PC Software

Manual (Driver Disk):If you do not have a full software suite installed, you can use the PC Adapter USB A2 Driverdisk V1.0 . Step 1: Close all background programs .

Step 2: Run Setup.exe from the driver disk as an Administrator .

Step 3: Follow the prompts to install the "Simatic Device Drivers" and restart your computer .

Step 4: Plug in the adapter; Windows should automatically detect it via the "Found New Hardware Wizard" . Open Set PG/PC Interface (Start > Siemens Automation

Path-Based Update:If the drivers are already on the system but not recognized, you can manually point Windows to the driver directory: Path: C:\Program Files\Siemens\Common\S7SDD .

Use the Device Manager, right-click the adapter, select "Update Driver," and browse to this specific folder . Hardware Specifications Interfaces: Connects to USB 1.1, 2.0, or 3.0 ports .

Protocols: Supports PROFIBUS (up to 12 Mbps) and MPI communication . Power: Fully powered via the USB interface . Verification & Troubleshooting Need drivers of PC ADAPTER USB A2 for windows XP

5.1 Set the Interface in Set PG/PC Interface

  • Open Set PG/PC Interface (Start > Siemens Automation > STEP 7).
  • In the "Access Path" tab, select "PC Adapter (MPI)" or "PC Adapter (Profibus)" from the list.
  • Click Properties.
  • In the "USB" tab, ensure the correct adapter is selected (usually "USB-0: Siemens PC Adapter USB A2").
  • In the "MPI" tab, set the transmission rate:
    • For S7-300: 187.5 Kbps
    • For S7-400: 1.5 Mbps (or 12 Mbps if Profibus)
    • Note: Windows XP’s timing stack can be unstable at 12 Mbps. If you get timeouts, lower the speed.

1. Obtain the Driver Files

You need these 4 files from a STEP 7 installation (v5.5 SP2 or later):

  • s7uo2pc.sys
  • s7u2pc64.sys (not used on XP 32-bit)
  • s7u2pcmd.INF
  • s7u2pcmd.cat

Alternative: Download from Siemens support (registration required):

  • Search entry ID: 27018891 or 57138768

Step 4: Verify in Device Manager.

  • Open Device Manager.
  • Expand “Siemens Devices” or “SIMATIC Devices” (sometimes under “Universal Serial Bus devices”).
  • You should see “Siemens PC Adapter USB A2” without a yellow exclamation mark.

Step 1: Check Your Step 7 Version

Before installing drivers, ensure your version of SIMATIC Step 7 supports the adapter.

  • Step 7 Classic (v5.5 + SP1 or higher): Full support for the A2 adapter.
  • Older versions (v5.4 or lower): You may need to install the "Simatic PC Adapter USB" driver pack separately or upgrade your Step 7 version.