Precision in Every Pulse: A Guide to the Weltouch CY-210B Weld Controller In the world of precision manufacturing, the Miyachi Weltouch CY-210B
serves as a critical brain for AC resistance welding. Known for its reliability in high-stakes industrial applications, this constant-current controller ensures that every weld nugget is consistent, even when power supplies or secondary circuits fluctuate.
If you are currently holding the manual or troubleshooting a unit, here is an "article-style" breakdown of what makes this piece of tech tick and how to navigate its setup. The Power of Constant Current Feedback The standout feature of the
(and its successor, the CY-210E) is its secondary constant current feedback. Instead of just sending a blind pulse of electricity, the controller examines each half-cycle of current flow in real-time. If it detects a change, it compensates instantly to maintain the programmed current. This is vital for maintaining joint strength in materials like high-strength steel. Core Technical Features
According to documentation from Amada Weld Tech and T. J. Snow, the CY-210B includes several sophisticated functions:
15 Weld Schedules: Users can pre-set 15 different profiles to quickly switch between different materials or thicknesses.
Dual Monitors: The unit features a built-in weld monitor and a conduction degree monitor, allowing you to see both what was programmed and what actually happened simultaneously.
Pulse Control: Supports "pulsation," as well as "up and down slope" (gradual increase or decrease of current) to prevent splashing and protect welding tips from overheating. Essential Manual Insights: Setup & Safety
The CY-210B User's Manual provides specific instructions for hardware integration:
Foot Switch Wiring: To connect a single-level foot switch, you typically use a jumper wire (min 24 AWG) between screw #11 and screw #10 on the back terminal block. The manual details binary combinations of these screws to select different weld schedules.
Handling Precautions: A key takeaway from the operational guidelines is sensitivity. You should never use a screwdriver or pen tip to press the buttons—always use your hand to avoid internal malfunctions.
Input Requirements: To initiate a weld sequence, the "START P" input must be active. The typical delay before welding begins is roughly 20 milliseconds. Why the Manual Matters
Whether you are working with an older pre-owned unit from a site like J316 Gallery or a modern equivalent, following the official Amada Weld Tech guidelines is the only way to ensure the "ideal welding current" is achieved without damaging the controller or the workpiece.
The Miyachi Weltouch CY-210B is a specialized resistance welding controller known for its secondary constant current feedback. While a single, complete digital manual is often archived or available through manufacturer support, here are the essential operating details and technical specifications sourced from official Amada Weld Tech documentation and technical addendums. Core Specifications & Features
Constant Current Control: The unit uses a toroidal coil to reconstruct current waveforms every half cycle, compensating for line voltage fluctuations to ensure smooth, consistent welding.
Memory Schedules: Users can store and recall up to 15 distinct weld schedules for rapid job switching.
Adaptability: The CY-210B is designed for a horizontal configuration and easily integrates into most existing contactor cabinets.
Input Requirements: Typical power sources range from 220V to 480V AC (50/60 Hz), depending on the shipment configuration. Key Setup Instructions
Dual-Level Foot Switch Connection: To connect a foot switch, wires for Level One and Level Two must be verified with a continuity checker. According to the CY-210B Addendum, wires from both levels are often shared at specific screw terminals (e.g., screw #6) to initiate different weld schedules. DIP Switch Settings (DSW1-3):
OFF: Sets power-on timing output for external checkers like the MM-365A. ON: Activates flicker output (Weld ON / Cool OFF).
Weld Timing: The controller typically requires a 20ms to 60ms lead time after a start signal is input before welding begins. Troubleshooting & Maintenance
Error Indicators: The controller features dedicated LEDs for common faults, including SCR Short-circuit, Overtemp (thermal contact trip), No Current (broken toroidal coil), and Current/Conduction Limits. Safety Precautions:
Always install the unit on a firm, level surface away from water or combustible materials.
Ensure all operators use ear protection and that the shop is equipped with a fire extinguisher.
Individuals with pacemakers must stay clear of the welding area due to high-intensity magnetic fields.
Master the Miyachi Weltouch CY-210B: Your Essential Setup & Operation Guide If you are looking for the Weltouch CY-210B manual
, you are likely dealing with one of the most reliable secondary constant current AC welding controls on the market. Manufactured by Miyachi (now Amada Weld Tech
), the CY-210B is designed to provide high precision in resistance welding by examining each half-cycle of weld current flow to compensate for changes in real-time. Core Features of the Weltouch CY-210B
The CY-210B stands out for its ability to reduce downtime and scrap through consistent feedback loops. Key features include: Secondary Constant Current Feedback:
Continuously monitors and adjusts current during the welding process for maximum accuracy. 15 Weld Schedules:
Store and select up to 15 different configurations based on material thickness and type. Dual Monitors:
Built-in monitors for both weld current and conduction degree allow operators to view programmed vs. actual data simultaneously. Advanced Control Functions:
Includes two-stage initiation, pulsation, up/down slope, and preheat/post-heat settings. Setup and Wiring Basics According to the official addendum for the CY-210B
, proper wiring of foot switches is critical for safe operation: Single-Level Foot Switch:
Requires a jumper wire (minimum 24 AWG) between screw #11 and one terminal of the foot switch. Dual-Level Foot Switch:
Requires verifying wires for Level One and Level Two using a continuity checker before connecting them to screws #6, #7, and #11. DIP Switch Configuration:
Use the internal DIP switches (DSW1) to toggle between specific output modes, such as flicker output or timing for a weld checker. Safety and Maintenance Tips
To keep your welding controller operational and safe, follow these manufacturer precautions: Environment:
Install the controller on a firm, level surface away from water or combustible materials.
Ensure proper water cooling if using a thyristor contactor (typically requiring a flow rate of 5 L/min). Inspection:
Periodically check terminal connections. Improper connections can lead to electrical shock or fire hazards. Battery Life:
The internal lithium battery (BR 1/2AT2N) has a data holding period of approximately 5 years. Troubleshooting Common Errors
The CY-210B features self-diagnostics that display error codes for various issues: Current Upper/Lower Limit Error:
Triggered when actual current falls outside the ±49% monitoring window. Thermostat Error: Indicates overheating in the contactor or transformer. No-Power-Supply Error:
Often caused by a primary power source failure or improper fuse.
For detailed technical specifications or to request a full physical copy of the legacy manual, you can contact Amada Weld Tech Support step-by-step walkthrough for programming one of the 15 weld schedules?
Here is the content developed for the WELTOUCH CY-210B Manual.
Since the CY-210B is a specialized industrial capacitive touch screen controller (often used for monitor overlays or industrial PCs), this manual is structured as a Technical User Manual focusing on installation, calibration, Windows/Linux drivers, and troubleshooting.
Summary for Manual Purposes
If you are writing or looking for the manual, the LED Indicator is the feature described to the end-user, while the Output Modes are the features described to the installer/engineer.
Typical Manual Excerpt:
"The unit features a high-brightness LED indicator. When the sensor is activated by touch, the LED illuminates to confirm the input signal. If the LED does not light upon touch, please check the power supply connection."
The Miyachi Weltouch CY-210B Go to product viewer dialog for this item.
is a constant-current AC resistance welding controller. It is designed for precise industrial welding applications, offering advanced monitoring and feedback features to ensure consistent weld quality. Key Technical Features
provides several standard functions for high-performance welding:
Constant Current Control: Utilizes secondary constant current feedback to maintain stable output even with fluctuations.
Weld Monitoring: Features built-in monitors for weld current, conduction degree, and error detection for real-time data viewing.
Weld Schedules: Supports up to 15 distinct weld schedules that can be programmed directly.
Programmable Sequence: Standard functions include pulsation, up/down slope, forge delay, and pre/post-heat settings.
Dual Valve Outputs: Includes two valve output signals and nine stepper settings for increased operational flexibility. Operational Guidelines According to technical addendums from Amada Weld Tech:
Foot Switch Connection: To connect a dual-level foot switch, Level One and Level Two wires must be verified with a continuity checker and connected to specific screw terminals (e.g., screw #6 for common wires).
DIP Switch Settings: The internal DIP switch (DSW1-3) determines output behavior; turning it OFF sets it for a weld checker (like the MM-356A), while turning it ON enables flicker output.
Start Sequence: A "Start P" input must be turned on to begin the squeeze (SQ) period.
Automatic Shut-off: The unit may feature a 200 msec T2 timer if the start signal is removed prematurely. Successor Model
has largely been replaced by newer versions like the CY-210D and the current CY-210E, which maintain the same horizontal configuration but add updated digital interfaces and expanded current monitoring ranges up to 80,000 A.
For specialized non-contact temperature measurement products often confused with this industrial controller, you can refer to manuals like the ennoLogic eT210B for body infrared thermometers.
The Miyachi Weltouch CY-210B is a specialized AC resistance welding controller known for its secondary constant current feedback system. Designed to handle industrial-scale welding tasks, it provides precise control over current fluctuations, ensuring consistent weld quality even when line voltage varies.
Below is a comprehensive guide to understanding and operating the Weltouch CY-210B based on standard technical manuals and manufacturer specifications. Overview of the Weltouch CY-210B
The CY-210B is a horizontal-type constant welding controller. Its primary function is to monitor and adjust the welding current in real-time. By examining every half-cycle of the actual current flow, the unit compensates for secondary current changes caused by fluctuations in the power source or resistance in the welding circuit. Key Features
Constant Current Feedback: Maintains secondary current stability through a toroidal coil.
Memory Schedules: Can store up to 15 distinct weld schedules for rapid recall during different production runs.
Weld Monitoring: Built-in monitors allow for simultaneous viewing of programmed settings and actual weld data.
Advanced Control Functions: Includes pulsation, up/down slope, forge delay, and preheat/post-heat settings. Installation and Wiring
Proper installation is critical for both machine performance and operator safety. 1. Connecting a Dual-Level Foot Switch According to the official addendum for the CY-210B:
Identify the four wires from your foot switch: two for Level One and two for Level Two.
Screw #6: Connect one wire from Level One and one wire from Level Two together here.
Screw #7: Connect the remaining Level One wire for the "Start 1" schedule. Screw #11: Connect the remaining Level Two wire. 2. Power Requirements
The controller typically operates on various AC voltages (e.g., 220V to 480V) depending on the factory shipment settings. Always verify the voltage requirements on the unit's nameplate before applying power. Operating Instructions
The front panel features an LED screen that displays the weld schedule number, actual current, and set time. Setting a Weld Schedule
Select Schedule: Use the "VALVE-SCHED." key on the front panel to select one of the 15 available slots. Define Parameters:
Squeeze (SQ): Time for electrodes to apply force before current flows.
Weld 1 (W1) / Weld 2 (W2): The actual duration of current flow. Cooling (C1): Interval between pulsations.
Slope (S1/S2): Gradual increase or decrease of current to prevent splashing.
Hold (HO): Time the pressure is maintained after the current stops.
Current Setting: Current can typically be set from 1.0 to 80.0 kA. Maintenance and Safety Precautions
Pacemaker Warning: The magnetic fields generated by the welding process can interfere with pacemakers. Individuals with these devices must stay clear of the machine.
Protective Gear: Always wear leather gloves, long-sleeve jackets, and protective glasses to shield against spatters.
Battery Maintenance: The unit uses a lithium battery (BR 1/2AT2N) to hold data in memory. This battery typically lasts for about 5 years before needing replacement.
Environmental Protection: Keep the controller on a level surface away from water or combustible materials. Troubleshooting Common Errors
No Sequence Work: Ensure the start signal is correctly applied; some modes prevent sequence execution if signals are fed improperly.
Trouble Output: If the unit detects an error, the "Trouble" relay will close, and an error code will typically display on the LED. Use the "RESET" button to clear these errors once fixed.
For detailed technical diagrams or specific part repairs, users often consult specialized vendors like Radwell International or Amada Weld Tech for modern equivalents like the CY-210E.
Weltouch CY-210B (manufactured by Amada Weld Tech, formerly Miyachi) is a secondary constant-current AC resistance welding control. While no specific "blog post" exists for it, the official technical manuals and data sheets provide comprehensive details on its operation and maintenance. Manual & Technical Documentation
You can access the official documentation directly from the manufacturer and authorized distributors: Official Addendum & Manual: Amada Weld Tech provides the CY-210B User's Manual Addendum
, which includes critical terminal block identification and wiring instructions for single-level foot switches. Timing and DIP Switch Settings:
For specific power-on timing and flicker output configurations, refer to Addendum B Key Technical Specifications According to TJ Snow Company , the CY-210B features: Monitoring:
Built-in weld, conduction degree, and error monitors to view programmed vs. actual data simultaneously. Standard Functions:
Supports two-stage initiation, pulsation, up/down slope, forge delay, and pre/post-heat. Programming:
Allows for 15 weld schedules, 2 valve output signals, 9 steppers, and direct programming of actual weld current. Quick Setup Guide: Foot Switch Connection
If you are wiring a single-level foot switch, follow these steps from the Amada Weld Tech manual
Use a jumper wire (minimum 24 AWG), roughly 1 to 4 inches long. Connect one end of the jumper to on the terminal block.
Connect the other end of the jumper wire and one wire from the foot switch to
Consult the labels near the terminal block to confirm screw identification before powering the unit. or configuring a weld schedule for this unit? Resistance Welding Engineer Technical Writer
Weltouch CY-210B is an AC resistance welding control (specifically a horizontal type) produced by Amada Weld Tech
(formerly Miyachi). It is designed to provide stable, high-quality welding through secondary constant current feedback and a multi-stage power-on function. Official Manuals and Technical Documentation
If you are looking for the technical manual or specific wiring instructions, you can access these official resources from Amada Weld Tech CY-210B Addendum (Revision C) : Provides detailed instructions for Forge Weld Operation
using a 2-stage initiation switch and footer switch general information. CY-210B/CT-110B Addendum (Revision B) Basic Operation with a 2-stage initiation switch. Successor Model Manual ( : Since the CY-210B is an older model, the CY-210E Operation Manual
is often used as a reference for similar front panel layouts and diagnostic error codes. amada weld tech Key Specifications & Features
Weltouch CY-210B is a resistance welding controller manufactured by Amada Weld Tech
(formerly Miyachi Unitek). While a single "complete paper" in the sense of a scholarly article may not exist specifically for this model, the technical documentation and user manuals provide the comprehensive operational details you need. Technical Documentation & Resources CY-210B User's Manual Addendum
: This document covers critical wiring and installation, specifically for connecting Dual-Level Foot Switches Combined Addendum (CY-210B & CT-110B) : Provides detailed instructions for basic and forge weld operations using 2-stage initiation switches. Successor Model (CY-210E) Datasheet
: For general specifications like voltage ranges (220V–480V AC) and control methods (primary/secondary current feedback), you can refer to the Technical Datasheet
for the updated "E" series, which maintains many of the "B" series' core functions. amada weld tech Key Specifications Control Method
: Uses primary or secondary current feedback constant-current control via thyristor phase control. Current Settings : Typically ranges from 1.0 to 80.0 kA
: Supports multiple weld schedules (often up to 15 in similar Weltouch models) to handle different welding tasks. amada weld tech Wiring for Dual-Level Foot Switch According to the official addendum amada weld tech : Connect one wire to and the other to (Start 1 schedule). : Connect one wire to (common) and the other to Verification
: Always use a continuity checker to identify the wires for each level before connecting. If you are looking for specific troubleshooting codes programming steps
The Amada Weld Tech (Miyachi) Weltouch CY-210B is a secondary constant-current AC resistance welding controller designed for high-precision industrial applications. It is often paired with an SC-210 contactor to provide a complete control solution for AC resistance welding. Key Specifications & Performance Current Range: (Maximum settings range from
Weld Schedules: Up to 15 individual schedules can be programmed to handle different part thicknesses or material requirements.
Control Modes: Supports secondary constant current, primary constant current, and power supply voltage compensation. Control Speed: cycle for secondary or primary constant current.
Output Valves: Two valve output signals for versatile machine control. Advanced Features
Constant Current Feedback: Examines each half-cycle of actual weld current and compensates for fluctuations to ensure consistent results.
Built-in Monitoring: Includes standard monitors for current, conduction angle, and errors, allowing operators to view programmed vs. actual data simultaneously.
Sequence Functions: Features 3-stage power-on, upslope/downslope, pulsation, and forge delay to prevent splashing and protect electrode tips.
Counters: Equipped with three separate counters—production, shot, and total—to assist with maintenance and quality control. Foot Switch Wiring
The CY-210B can be used with either single-level or dual-level foot switches.
Terminal Connections: Foot switches are wired to a screw-type terminal block on the back of the unit.
Dual-Level Switch: Connects to pins for both "Level One" and "Level Two" (Start signals). For example, one wire from each level typically connects to screw #6 (Common), while the Level One wire goes to #7 (Start 1) and Level Two to #11.
Single-Level Switch: Requires a jumper wire (min 24 AWG) between screw #11 and another terminal to bypass the second level. Maintenance & Operations
Electrode Care: After changing electrodes, manually push the weld head through its full stroke (e.g.,
) to reset bearing cages that may have migrated due to vibration.
Safety: Always connect the ground wire to the transformer output terminal that is linked to the weld head ground to prevent electric shock.
For further setup details, refer to the official Amada Weld Tech Support for digital manuals. CY-210B User's Manual - amada weld tech
Page 4. CY-210B USER'S MANUAL. Page 5-2, After Step 6) "Pins 7-11," Add: FOOT SWITCH GENERAL INFORMATION. ADDENDUM 995-037, REV C. amada weld tech
The Miyachi Weltouch CY-210B is a high-performance constant current resistance welding controller designed for precision and reliability in industrial welding applications. Manufactured by Amada Weld Tech (formerly Miyachi), this horizontal-type controller specializes in secondary constant current feedback to ensure consistent weld quality despite line voltage fluctuations. Key Features of the CY-210B
The CY-210B is engineered to adapt easily to existing contactor cabinets and provides advanced control over the welding process.
Constant Current Feedback: Utilizes a toroidal coil to monitor weld current every half-cycle, correcting for variations to maintain smooth, consistent output.
Multiple Welding Schedules: Supports up to 15 distinct weld schedules that can be stored in memory for instant recall during different production runs.
Integrated Monitoring: Features built-in monitors for both current and conduction degrees, allowing operators to view programmed versus actual conditions simultaneously.
Step-Up Functionality: Includes 9-step current steppers for two schedules, helping to manage electrode wear and maintain consistent heat. Technical Specifications Specification Control Method
Secondary/Primary Constant Current, Power Voltage Compensation Current Range 1 kA to 80 kA (Maximum setting: 5 kA to 80 kA) Timer Settings 00–99 cycles for Squeeze, Weld, and Hold periods Valve Outputs 2 schedules; 100 VAC (max 1 amp) or 24 VDC Triac control Pulsation Adjustable from 1–9 times Setup and Operation Basics
According to the CY-210B Addendum provided by Amada Weld Tech, proper installation and configuration are critical for safety and performance. Connecting a Foot Switch
Single-Level Switch: Requires a jumper wire between specific screws (typically screw #11 and #1) on the back terminal block to activate basic start signals.
Dual-Level Switch: Level one and level two wires must be verified with a continuity checker. Common wires often connect to screw #6, while specific start signals connect to screws #7 and #11 depending on the schedule. Programming Weld Schedules
The controller uses an easy-to-read LED screen to display schedule numbers and current settings.
Select Schedule: Use the keyboard to navigate to the desired schedule number (1–15).
Set Current: Define the target kA. The microcomputer automatically adjusts phase control to meet this target.
Adjust Timers: Set cycles for Squeeze (SQ), Weld (W1, W2, W3), Cool (C1, C2), and Hold (HO) phases to optimize the thermal profile for your material. Safety and Maintenance
Personal Safety: Magnetic fields generated during operation can interfere with pacemakers; individuals with such devices must avoid the welding area while the machine is active.
Protective Gear: Always wear leather aprons, long-sleeved jackets, and protective glasses to shield against spatters.
Device Care: Avoid inserting metal objects like screws or coins into the controller housing, as this can cause permanent electrical failure.
For detailed troubleshooting or replacement parts, retailers like Radwell International offer refurbished units and repair services.
The Amada Miyachi Weltouch CY-210B is a high-precision AC resistance welding controller designed to provide secondary constant current feedback. This "horizontal type" controller ensures stable welding current by monitoring and correcting the current flow every half cycle, compensating for line voltage fluctuations and load changes. Core Specifications
The CY-210B is characterized by its ability to store and recall complex welding sequences.
Current Range: 1 kA to 80 kA (Maximum current setting of 5 kA to 80 kA).
Memory Capacity: Up to 15 unique weld schedules can be stored for instant recall. Control Speeds: Secondary Constant Current: 1/2 Cycle. Primary Constant Current: 1/2 Cycle. Primary Voltage: 1 Cycle. Timer Settings: Squeeze time from 00 to 99 cycles. Key Operational Features
Constant Current Feedback: Using a toroidal coil, the system reconstructs the current waveform to an RMS effective value, correcting the output through phase conversion and trigger pulse oscillation.
Monitoring System: Includes built-in monitors for both weld current and conduction degrees, allowing users to view programmed vs. actual conditions simultaneously.
Foot Switch Compatibility: The unit supports both single-level and dual-level foot switches.
Dual-level setup: Level One and Level Two wires connect to specific terminal screws (e.g., screw #6, #7, and #11) to initiate different weld schedules.
Integration: Designed to be easily adaptable to most existing contactor cabinets, such as the SC-210. Installation & Safety Guidelines
According to the CY-210B User Manual Addendum, proper wiring is critical for safe operation:
Wiring Verification: Use a continuity checker to identify foot switch levels before connecting to the terminal block. Safety Precautions:
Pacemakers: Individuals with pacemakers must stay clear of the machine due to strong magnetic fields.
Protective Gear: Operators should wear leather aprons, long-sleeve jackets, and safety glasses to protect against spatters.
Cable Care: Do not twist, pull, or walk on power cables to prevent fire or electric shock. Summary of Maintenance & Troubleshooting
Lithium Battery: The internal BR 1/2AT2N battery holds data for approximately 5 years.
Reset Functions: A dedicated "Count Reset" key allows for clearing total weld counts or workpiece-specific data.
Error Indicators: The system detects and outputs trouble signals (such as "No-Weld Error 07") if power supply or contact connections are inverted.
For full technical details, you can refer to the official Amada Weld Tech documentation or specific addendums for this model. CT-110D
Conclusion
The Weltouch CY-210B is a versatile touch controller that can elevate your project’s user experience. By following this guide, you’ll streamline setup, avoid common pitfalls, and ensure long-term reliability. For detailed specifications or firmware downloads, always refer to the official Weltouch CY-210B manual or contact their support team. Happy building!
Need Help Faster?
Download the CY-210B Datasheet | Visit Weltouch’s Support Page | Join Our DIY Community Forum
SEO Keywords: Weltouch CY-210B manual, capacitive touch controller guide, CY-210B setup, TouchWin calibration, capacitive touch troubleshooting.
This guide balances instructional depth with practical accessibility, ensuring engineers and hobbyists can harness the CY-210B’s full potential.
Title: The Weltouch CY-210B Manual: Why You Need to Ditch the Paper and Master the Multi-Function Meter
Subtitle: Unlocking the secrets of your soil, light, and pH meter without the tiny, confusing font.
Let’s be honest. You bought the Weltouch CY-210B because you saw those lush, green photos online and thought, “I need that. My plants are dying, and I need to know why.”
It arrived. You pulled out the instruction manual... and immediately regretted it.
That tiny, folded sheet of paper with 12 languages crammed into 4 square inches? It leaves a lot to be desired. If you’ve lost the original Weltouch CY-210B manual (or just can’t read the microscopic text), you’ve come to the right place.
Here is the real-world manual for your 3-in-1 wonder gadget.
The 3 Biggest Mistakes (Read this before you break it)
Mistake #1: Testing right after watering. You just watered, and the meter says "Wet." No kidding. Wait 30-45 minutes for the water to distribute evenly through the soil before testing.
Mistake #2: Leaving it in the soil. The CY-210B is a tester, not a monitor. Leaving the metal probes in wet soil for days will corrode the copper and ruin the meter. Test, record, remove, wipe clean.
Mistake #3: Testing rock-hard soil. Those probes are sensitive. If your soil is compacted like concrete, use a screwdriver to pre-drill a pilot hole. Pushing too hard will bend the probes permanently.
Battery Replacement Schedule:
- Replace batteries once per year, even if the low battery warning (E3) has not appeared.
- Always use fresh Alkaline batteries. Do not use rechargeables (lower voltage causes erratic behavior).
- When replacing batteries, the schedule and time may reset. Keep a note of your program settings before popping the batteries out.
2. Package Contents
- 1x CY-210B Controller Board
- 1x USB Cable (A to B, 1.5m)
- 1x FPC Cable (for connecting to touch sensor, 2.0mm pitch)
- 4x M3 Mounting Screws
- (Optional: Grounding wire for EMI shielding)
Typical accessories included
- Lanyard
- Carrying pouch/case
- User manual and warranty card
- Two AAA batteries (sometimes included)